HM-410 Advanced 3-Floor Lift Educational Lab Equipment Mechatronics Training Equipment
The automation process with the 3-floor lift mod. HM-410 enables the theoretical analysis and the experiments on the following main exercises: microswitches, relays, ON/OFF drives of a DC motor et lift systems.
TECHNICAL SPECIFICATIONS
- Treated and epoxy-painted steel structure reproducing a3-floor lift.
- Insulating material side synoptic panel with 4mm-dia. Safetyterminals for the electrical connections to any PLC or controlboard; 25 pin-connectors for quick connection to our PLC training panel mod. PLC-V7 (not included).
- 3 automatic doors with opening/closing electrical motors.
- 1 automatic cabin door with opening/closing electrical motorand photocell for users’ safety.
- 4 microswitches for doors closing control.
- 3 limit microswitches for cabin stop at each floors.
- 4 limit microswitches for the cabin floors approach.
- 2 microswitches for cabin over travel.
- Cabin motion with electrical motor controlled by relays UP/DOWN and speed-change.
Pushbuttons and limit switches refer to a common terminal with no electrical potential, the actuating/signaling devices accept input electrical signals in 5 to 24Vdc range.
Electrical elements available for PLC and interface boards connections with to 4mm-dia. safety terminals.
1st FLOOR
- Floor call pushbutton with NO contact
- ‘On-service’ signaling LED
- Limit switch for ‘closed door’ signaling
- Motor control for 1st floor door closing
- Motor control for 1st floor door opening
2nd FLOOR
- Floor call pushbutton with NO contact
- ‘On-service’ signaling LED
- Limit switch for ‘closed door’ signaling
- Motor control for 2nd floor door closing
- Motor control for 2nd floor door opening
3rd FLOOR
- Floor call pushbutton with NO contact
- ‘On-service’ signaling LED
- Limit switch for ‘closed door’ signaling
- Motor control for 3rd floor door closing
- Motor control for 3rd floor door opening
CABIN
- Pushbutton for motion to 1st floor, NO contact
- Pushbutton for motion to 2nd floor, NO contact
- Pushbutton for motion to 3rd floor, NO contact
- LED for signaling cabin at 1st floor
- LED for signaling cabin at 2nd floor
- LED for signaling cabin at 3rd floor
- STOP pushbutton with NC contact
- Emergency call pushbutton, NO contact
- Limit switch for ‘closed door’ signaling
- Cabin reflection photocell for users’ safety
- Motor control for cabin door opening & closing
COMMON DEVICES
- Motor control for cabin upward / downward
- Motor control for cabin-motion first / second speed.
- Limit microswitch for cabin stop at 1st floor
- Limit microswitch for cabin stop at 2nd floor
- Limit microswitch for cabin stop at 3rd floor
- Limit microswitch for cabin low over travel stop
- Limit microswtich for cabin top over travel stop
- Limit microswitch for cabin approaching to 1st floor
- 2 limit microswitches for cabin approaching to 2nd floor
- Limit microswitch for cabin approaching to 3rd floor
- Eelectronic ringtone for emergency
- Mechanic characteristics:
– Silk screen synoptic
– Sheet steel structure painted
– Plexiglas transparent panel
– DC gear motor coupled to a system of pulleys with a belt for the cabin motion
A PLC (not included) is needed to control the process. Minimum requirements:
- 21 24 Vcc digital inputs
- 16 24 Vcc 0,5 A digital outputs
Suggested PLC:
- n° 1 PLC training panel mod. PLC-V7 with programmingand simulation software mod. SW7
Alternative:
- n° 1 PLC training panel mod. PLC-V6
Power Supply: 230 Vca 50 Hz Single-phase (Other voltage and frequency under request)
Dimensions: 500 x 350 x 600 mm
Weight: 15 kg